![]() ![]() If 30 days have gone by since your purchase, unfortunately we can’t offer you a refund or exchange. You are personally and fully responsible for payment of any medical equipment or supplies you purchase from this website. If you purchase any medical equipment or supplies from the diabetic or bargain section of our website and submit a claim to Medicare for those items, Medicare will not pay. Monitors glucose control levels 1 and 2ĪTTENTION MEDICARE PATIENTS: is NOT an accredited Medicare supplier.Accu-Chek test strips for single patient usage.Assessment bands for blood sugar analysis.Accu-Chek Inform II Test Strips, 50-count: Suitable for self-testing, these blood glucose test strips can help reveal important information about patterns and place you on the path to controlling diabetes while maintaining vitality and wellness. Accu-Chek Inform II bands are easy to use and can generate a reading with just a drop of plasma from the palm or fingertip. Other factors such as stress, physical activity or surgery can also contribute to sugar fluctuations in the body. Even with regular diet and exercise, blood sugar levels can alternate. The suspect product was requested to be returned, however, the customer no longer has the vial of strips that were used for the aforementioned tests.For use with Accu-Chek Inform II Blood Glucose MeterĪccu-Chek Inform II Test Strips are an efficient way to monitor your glucose levels. The patient's symptoms improved after they were given the d50.Īll of the results were obtained using strips from the same vial of strips. The patient was tested again at 7:02am on this meter and obtained a result of 271 mg/dl. Lo indicates the blood glucose is below 10 mg/dl.Īt that point the nurse gave the patient d50. The nurse then tested the patient again on inform ii meter (serial number (b)(4)) at 6:54 am and received a result of lo. The patient symptoms of stomach pain and shaking became worse. The nurse gave the patient 10 units of novolog as treatment since she had misinterpreted the previous results of rr lo to mean the patient's blood glucose was high. The nurse then tested the patient on a second inform ii meter (serial number (b)(4)) at 6:49am. She tested the patient again at 6:20 am and at 6:33 am with a result of rr lo on the same meter. ![]() ![]() It was further reported that the nurse did not treat the patient with d50 as she should of have based on the result. The nurse testing the patient interpreted the results of rr lo to be a high blood sugar, however, the alarm was notifying them that the results were actually below the institution's defined reportable range. The reportable range for the facility is 20 mg/dl to 600 mg/dl. Rr lo is an alarm set by the institution for results that are below their defined reportable range threshold but are within the system measurement range of 10 mg/dl to 600 mg/dl. They were tested on the same meter at 6:19 am and a result of rr lo was obtained. On the morning of (b)(6) 2015, the caller stated that the patient was feeling low symptoms of stomach pain. A patient was tested on (b)(6) 2015 at 6:06 pm on inform ii meter (serial number (b)(4)) and received a result of 235 mg/dl with no symptoms.
0 Comments
Leave a Reply. |
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |